Living room scene with blue walls, a couch, coffee table, blanket, and decorations.

Existing Ceiling Soundproofing Assemblies

Cow Spots
best existing ceiling soundproofing BEST Existing Ceiling Soundproofing Assembly Angle Down

BEST Existing Ceiling Soundproofing Assembly Soundproofing Methods

Instructions for Installation – Best Existing Ceiling Soundproofing

1. Use a stud finder to locate the joists within the ceiling. Mark the joists with a chalk line.

2. Using the chalk lines as a guide, install the isoTRAX™ Soundproofing System onto the existing ceiling surface.

3. Install the Echo Absorber™ Acoustic Panels between the isoTRAX™ rails.

4. Install ½ inch Type X gypsum board on to the isoTRAX™ system with 1 ¼ inch fine thread drywall screws. Screws should be placed 8 inches apart. Leave a ¼ inch gap between the new layer of gypsum board and all adjoining wall, ceiling and floor surfaces.

5. Fill the ¼ inch gap with OSI® Pro-Series® SC-175™ Acoustical Sound Sealant.

6. Finish the gypsum board using common industry standards.

Note: For increased performance add another layer of 5/8 inch Type X Gypsum board.

Continue Reading

GOOD Existing Ceiling Soundproofing Assembly

existing ceiling good soundproofing GOOD Existing Ceiling Soundproofing Assembly Angle Down

GOOD Existing Ceiling Soundproofing Assembly Soundproofing Methods

Instructions for Installation – Good Existing Ceiling Soundproofing

1. Use a stud finder to locate the joists within the ceiling. Mark the joists with a chalk line.

2. Lay the ½ inch drywall face down on to a clean dry surface. Apply a ¼ inch bead PL Construction Adhesive around the perimeter of the backside of the drywall. Apply the adhesive approximately 2 inches from the edge of the drywall. Create an X pattern corner to corner and place a few 1 inch “globs” of glue with the field.

3. Place the Quiet Barrier® material onto the back side of the drywall. To ensure good contact with the adhesive, use a hand roller to apply pressure. Let the adhesive cure for 24 hours before installation.

4. Attach the drywall / Quiet Barrier® composite with 2 inch coarse thread drywall screws. Be sure the screws penetrate the joists within the wall assembly. Screws should be placed 8 to 12 inches apart.

5. Leave a ¼ inch gap between the new layer of gypsum board and all adjoining wall, ceiling and floor surfaces.

6. Fill the ¼ inch gap with OSI® Pro-Series® SC-175™ Acoustical Sound Sealant.

7. Finish the gypsum board using common industry standards.

Note: For increased performance add another layer of 5/8 inch Type X Gypsum board.

Continue Reading